A magnetic chuck can clear access around a ferromagnetic workpiece. Holding performance depends on the material, thickness, contact area, air gap and how the part bridges the poles. Aluminum is not held directly by a conventional magnetic chuck.
Match the workpiece to the chuck
Use the chuck maker’s limits for the actual material and minimum workpiece thickness. Check the contact surface for chips, scale or waviness. If pole extensions are used, verify their placement and support so the part does not rock or bend under the expected load.
Check resistance to cutting loads
Evaluate lateral forces and tipping moments as well as the normal holding force. Use approved stops where appropriate and prove out the actual cut under controlled conditions. Plan how the chuck will be released and whether residual magnetism matters for downstream cleaning or inspection.
When a magnetic chuck cannot hold a nonferrous part, consider Vacuum Workholding for Aluminum Parts.
For related planning, see how to qualify a CNC fixture. If you need a process reviewed around your machine, fixture and part mix, contact Prolific CNC for manufacturing consulting.